DDB#
Name
CAS-RN
Formula
174
Water
7732-18-5
H
2
O
Overview
Details
210
Ammonia
7664-41-7
H
3
N
Overview
Details
1050
Carbon dioxide
124-38-9
CO
2
Overview
Details
6304
Sodium carbonate
497-19-8
CNa
2
O
3
Overview
Details
6311
Sodium sulfate
7757-82-6
Na
2
O
4
S
Overview
Details
6653
Ammonium carbonate
506-87-6
CH
8
N
2
O
3
Overview
Details
13444
Ammonium hydroxide
1336-21-6
H
5
NO
Overview
Details
Search for mixtures containing this mixture as subsystem
Search data for binary subsystems
Mixture Data
Databank
Sets
Points
Temperature
Range
Pressure
Range
Vapor-Liquid Equilibria
VLE
42
1252
293-680 K
4-24700 kPa
174
210
1050
41
1050
6304
6311
1
Gas Solubilities
GLE
12
76
293-313 K
0-101 kPa
174
210
1050
12
Gas Solubilities - Electrolyte Systems
EGLE
87
482
273-646 K
4-19730 kPa
174
210
6311
8
174
1050
6304
1
174
1050
6311
78
(A)zeotropic Data
AZD
6
6
373-473 K
n.a.
174
210
1050
6
Vapor-Liquid Equilibria of Electrolyte Systems
ELE
10
115
299-393 K
7-3101 kPa
174
210
1050
6311
7
174
210
6311
3
Densities and Volumes of Mixtures, Excess Volumes
VE
1
18
298 K (const.)
n.a.
174
6304
6653
1
Salt Solubilities
ESLE
29
223
273-623 K
100-19730 kPa
174
210
1050
6304
6311
6653
13444
1
174
210
1050
6311
2
174
210
6311
5
174
1050
6311
2
174
6304
6311
17
174
6304
6653
2
Mixture Viscosities
VIS
3
18
283-313 K
88 kPa (const.)
174
210
6304
2
174
6304
6311
1
Mixture Surface Tensions
MSFT
2
24
343-373 K
2000-50000 kPa
174
1050
6311
2
Mixture P-v-T Data
MPVT
1
25
433-473 K
7250-16660 kPa
174
210
1050
1
Gas Hydrate Data
GHD
1
8
272-281 K
1220-3820 kPa
174
1050
6311
1
Electrical Conductivities
ECND
2
3
283 K (const.)
n.a.
174
210
6304
2
Diffusion Coefficients
DIF
4
24
288-308 K
101 kPa (const.)
174
1050
6311
4
Further Thermodynamic Properties
X
41
693
283-393 K
101-13110 kPa
174
210
1050
24
174
210
1050
6311
1
174
210
13444
1
174
1050
6304
4
174
1050
6311
2
174
1050
6653
9
Total
241
2967
174
210
1050
84
174
210
1050
6304
6311
6653
13444
1
174
210
1050
6311
10
174
210
6304
4
174
210
6311
16
174
210
13444
1
174
1050
6304
5
174
1050
6311
89
174
1050
6653
9
174
6304
6311
18
174
6304
6653
3
1050
6304
6311
1
Dortmund Data Bank Version: February 2024