Online DDB Search

Dortmund Data Bank
Thermophysical Data for Process Design
Contact: ☎ +49 441 361819 0 or ✉ info@ddbst.com

Query

A quote for experimental literature data about the system can be obtained via email.
DDB# Name CAS-RN Formula
174 Water 7732-18-5 H2O Overview Details
546 Monoethanolamine 141-43-5 C2H7NO Overview Details
894 2,2'-Diethanolamine (DEA) 111-42-2 C4H11NO2 Overview Details
1050 Carbon dioxide 124-38-9 CO2 Overview Details
1061 Dinitrogen monoxide 10024-97-2 N2O Overview Details
2187 Methyldiethanolamine (MDEA) 105-59-9 C5H13NO2 Overview Details
Search for mixtures containing this mixture as subsystem
Search data for binary subsystems

Mixture Data

Databank Sets Points Temperature
Range
Pressure
Range
Vapor-Liquid Equilibria VLE 49 441 274-423 K2-19750 kPa
174 546 1050
7
174 546 2187
3
174 894 2187
4
174 1050 2187
22
174 1061 2187
13
Gas Solubilities GLE 1057 7790 273-478 K0-641691 kPa
174 546 894 1050
6
174 546 1050
291
174 546 1050 2187
69
174 546 1061
34
174 546 1061 2187
10
174 894 1050
186
174 894 1050 2187
49
174 894 1061
27
174 894 1061 2187
19
174 1050 2187
323
174 1061 2187
43
Liquid-Liquid Equilibria (Miscibility Gaps) LLE 2 17 274-298 K3200-20570 kPa
174 1061 2187
2
Heat Capacities of Mixtures, Excess Heat Capacities CPE 43 502 298-353 Kn.a.
174 546 1050
5
174 546 1050 2187
3
174 546 2187
12
174 894 1050
4
174 894 1050 2187
3
174 894 2187
12
174 1050 2187
4
Solid-Liquid Equilibria SLE 1 32 253-272 Kn.a.
174 546 2187
1
Densities and Volumes of Mixtures, Excess Volumes VE 118 911 288-423 K101-808 kPa
174 546 1050
5
174 546 2187
42
174 894 1050
16
174 894 2187
39
174 1050 2187
16
Mixture Viscosities VIS 256 2639 293-423 K100-100000 kPa
174 546 894
25
174 546 1050
118
174 546 1050 2187
15
174 546 2187
23
174 894 1050
7
174 894 1050 2187
15
174 894 2187
26
174 1050 1061 2187
1
174 1050 2187
25
174 1061 2187
1
Mixture Surface Tensions MSFT 118 1098 288-373 K100-14270 kPa
174 546 1050
34
174 546 1050 2187
23
174 546 2187
13
174 894 1050
23
174 894 1050 2187
3
174 894 2187
14
174 1050 2187
8
Mixture P-v-T Data MPVT 43 1312 293-423 K5-140000 kPa
174 894 1050
13
174 894 2187
12
174 1050 2187
18
Gas Hydrate Data GHD 2 11 275-279 K1500-2310 kPa
174 1050 1061
2
Electrical Conductivities ECND 4 20 298 K (const.)100 kPa (const.)
174 546 1050
4
Diffusion Coefficients DIF 60 587 288-368 K101 kPa (const.)
174 546 1050
5
174 546 1061
8
174 894 1050
8
174 894 1050 2187
3
174 894 1061
5
174 894 1061 2187
2
174 894 2187
1
174 1050 2187
6
174 1061 2187
22
Further Thermodynamic Properties X 458 33992 120-422 K1-10000 kPa
174 546 894 1050 1061 2187
1
174 546 1050
121
174 546 1050 1061
8
174 546 1050 2187
15
174 546 1061
2
174 894 1050
95
174 894 1050 1061
1
174 894 1050 2187
20
174 894 1061 2187
1
174 894 2187
1
174 1050 1061 2187
6
174 1050 2187
187
Total 2211 49352
174 546 894
25
174 546 894 1050
6
174 546 894 1050 1061 2187
1
174 546 1050
590
174 546 1050 1061
8
174 546 1050 2187
125
174 546 1061
44
174 546 1061 2187
10
174 546 2187
94
174 894 1050
352
174 894 1050 1061
1
174 894 1050 2187
93
174 894 1061
32
174 894 1061 2187
22
174 894 2187
109
174 1050 1061
2
174 1050 1061 2187
7
174 1050 2187
609
174 1061 2187
81

Dortmund Data Bank Version: February 2024
What are "Sets" and "Points" in the Dortmund Data Bank? © Dortmund Data Bank  by  DDBST GmbH
Online DDB search information page Overall Statistics on Systems, Sets, and Points
Contact Direct link to this DDB search page
(0.73 seconds)